Hampton 蛋白结晶优化试剂 Optimization Screens

Hampton 蛋白结晶优化试剂 Optimization Screens

1、Solubility & Stability Screen  蛋白特异性试剂优化溶解性和稳定性
Protein specific agents for optimization of solubility & stability  
2、Solubility & Stability Screen 2   离子缓冲液
Buffer, pH & ionic strength screen for optimization of solubility & stability
3、Slice pH    PH缓冲液
pH & buffer screen for optimization of crystals or sample solubility & stability
4、Additive Screen  96孔板添加剂试剂盒
96 compound screen for optimization of crystal size & quality
5、Silver Bullets • Silver Bullets Bio
Small molecule additive screen for optimization of crystal size & quality
6、Detergent Screen
Detergent screen for optimization of crystals or sample solubility & stability
7、Ionic Liquid Screen
Ionic liquid additive screen for optimization of crystal size & quality
8、StockOptions Buffer Kits
Titrated buffer sets for optimization of crystals or sample solubility & stability
9、StockOptions Polymer
n of crystal size & quality
10、StockOptions Salt
Salt reagent kit for optimization of crystal size & qualit
11、Polymer reagent kit for optimizatioy
Proti-Ace
In situ proteolysis kit protein for crystallization screening & optimization
12、Reductive Alkylation
Reductive alkylation kit for crystallization screening & optimization
13、Silica Hydrogel Kit
pH neutral silica hydrogel matrix crystallization
14、Low Melting Agarose
Agarose gel matrix crystallization
15、CryoPro
Water soluble cryoprotectant reagent set
16、Heavy Atom Screens
Heavy atom kits for multiple isomorphous replacement
17、I3C Phasing Kit
Produce heavy atom derivative of biological macromolecules for phasing

Hampton蛋白结晶小瓶和结晶柱底座CrystalCap™

Hampton蛋白结晶小瓶和结晶柱底座CrystalCap™

Applications

Cryocrystallography  低温结晶学
Features

SSRL style sample mount for cryocrystallography
CrystalCap attaches magnetically to CrystalCap Vial and Magnetic Goniometer Base
Conical shape with ledge compatible with SSRL style grippers, auto mounters and sample handlers

Description
The CrystalCap is a magnetic sample mount (also known as a cap, pin or goniometer base) designed for cryocrystallography systems that accept SSRL style sample mounts. The CrystalCap attaches to a magnetic CrystalCap Vial and Magnetic Goniometer Base. The tip of the CrystalCap accepts a Mounted CryoLoop™ or MicroTube™ fitted with a CryoLoop™.
The CrystalCap Vial is a 1.8 ml cryo vial featuring two small vents. A ring magnet is molded into the open end of the vial so that when the cap is positioned in the vial, the ring magnet holds the cap on the vial during cryogenic storage.The HR4-904 CrystalCap Vial does not have a magnet on the bottom of the vial.
The conical shape with ledge is compatible with SSRL style grippers, auto mounters and sample handlers.
Compatible with the following Synchrotron Radiation Beamlines
North & South America
• The Advanced Light Source, Berkeley, California ALS 4.2.2, ALS 11.3.1, ALS 12.2.2, ALS 12.3.2
• The Advanced Photon Source, Argonne, Illinois APS 14-BM-C BioCARS, APS 14-ID-B BioCARS
• Cornell High Energy, Synchrotron Source, Ithaca, New York CHESS A1, CHESS F1
• Canadian Light Source, Saskatchewan, Canada, CLS 08ID-1, CLS 08B1-1
• National Synchrotron Light Source, Upton, New York NSLS X4C
• Stanford Synchrotron Radiation Laboratory, Menlo Park, California SSRL BL7-1, SSRL BL9-1, SSRL BL9-2, SSRL BL11-1, SSRL BL12-2, SSRL BL14-1
Asia & Australia
• Shanghai Synchrotron Radiation Facility, Shanghai, China SSRF BL17U1
• National Synchrotron Radiation Research Center, Taiwan NSRRC BL13B1, NSRRC BL13C1
• Pohang Accelerator Laboratory, Pohang, South Korea PAL 2D, PAL 5C, PAL 7A
• Photon Factory, Tsukuba, Japan PF BL-5A, PF BL-17A, PF AR-NW12A
• Super Photon ring-8 GeV, Japan SPRING-8 BL12B2, SPRING-8 BL24XU, SPRING-8 BL26B1, SPRING-8 BL26B2, SPRING-8 BL32B2, SPRING-8 BL32XU, SPRING-8 BL38B1, SPRING-8 BL41XU, SPRING-8 BL44B2, SPRING-8 BL44XU
CrystalCap™
CrystalCap
CrystalCap™
CrystalCap & Vial
CrystalCap™
CrystalCap
Hampton蛋白结晶小瓶和结晶柱底座 CrystalCap™

CAT NO NAME DESCRIPTION
HR4-733 CrystalCap with Vial – 60 pack
HR4-902 CrystalCap without Vial – 60 pack
HR4-904 CrystalCap Vial Vial only – 30 pack

Hampton 蛋白结晶试剂–Crystal Screen

Hampton 蛋白结晶试剂–Crystal Screen
Crystal Screen • Crystal Screen 2 • Crystal Screen HT

Applications
 Primary screen for proteins, soluble peptides, nucleic acids, & water soluble small molecules
 Sparse matrix additive screen
Features
 The original sparse matrix screen
 Sparse matrix formula efficiently samples salts, polymers, organics, & pH
 Proven effective with more than 1,000 biological macromolecules
 Tube or Deep Well block format

Description
The Crystal Screen and Crystal Screen 2 reagent kits are designed to provide a highly effective and rapid screening method for the crystallization of macromolecules. The screens are simple and practical for finding initial crystallization conditions. The initial crystallization conditions for more than 1,000 proteins, peptides, oligonucleotides, and small molecules have been determined using Crystal Screen.
A highly effective approach to overcome the exhaustive search for suitable crystallization conditions is the use of a sparse matrix method of trial conditions that is biased and selected from known crystallization conditions for macromolecules. The formulation utilized in Crystal Screen and Crystal Screen 2 evaluates 96 unique mixtures of pH, salts, polymers and organics, and their ability to promote crystal growth.
Crystal Screen contains 50 unique reagents, 10 ml each and is based on the sparse matrix formulation first described by Jancarik and Kim in 1991.
Crystal Screen 2, an extension of Crystal Screen, contains 48 unique reagents, 10 ml each and is based on the formulation first described by Cudney et al in 1994.
Crystal Screen HT contains 1 ml each of reagents 1-48 from Crystal Screen and all 48 reagents from Crystal Screen 2 in a single Deep Well block format.
Ready-to-use reagents are sterile filtered and formulated with ultra-pure Type 1 water, using the highest purity salts, polymers, organics and buffers. Individual reagents are available through the Hampton Research Custom Shop.
Crystal Screen • Crystal Screen 2 • Crystal Screen HT
Crystal Screen • Crystal Screen 2 • Crystal Screen HT
Crystals of a carbohydrate processing enzyme grown using Hampton Research Crystal Screen. Shirley Roberts, York Structural Biology Laboratory, York, United Kingdom.
Crystal Screen • Crystal Screen 2 • Crystal Screen HT
Crystal of zRFP574 red fluorescent protein grown using Hampton Research Crystal Screen 2. Pletneva et al. Acta Cryst. D62, 527-532 (2006). Nadya, Russian Academy of Science, Moscow, Russia.

CAT NO NAME DESCRIPTION
HR2-110 Crystal Screen 10 ml, tube format
HR2-112 Crystal Screen 2 10 ml, tube format
HR2-130 Crystal Screen HT 1 ml, Deep Well block format

Hampton蛋白结晶工具及仪器

Hampton蛋白结晶工具及仪器
CryoTong™ – Long
ApplicationsCrystal transfer under cryo temperature
FeaturesArtery clamp style closure30 seconds of cryo temperature180 mm length
Description
The CryoTong is a tool used to manually transfer a crystal mounted on a CrystalCap™ from liquid nitrogen to a magnetic base in a goniometer head positioned in a cryogenic stream, and then back to liquid nitrogen. The one-piece, compact CryoTong is available in two lengths. The long CryoTong is approximately 180 mm in overall length. The artery clamp style maintains the CryoTong in the closed position until the clamp is squeezed, which opens the opposing heads. The heads are non-magnetic stainless steel. The handle is magnetic stainless steel. The inside of the head is machined to closely surround the CrystalCap with loop and crystal in place. A small retaining lip is machined into the lower portion of the head to prevent the CrystalCap from slipping out of the CryoTong when the tool is in the closed position. The CryoTong can maintain the temperature of the crystal at -160°C for up to 30 seconds during room temperature crystal transfers. Choose the proper CryoTong size based upon the pin length required by the configuration of the x-ray data collection hardware used. The 18 mm CryoTong (HR5-112) is to be used with the CrystalCap HT and any other CrystalCap configured for 18 mm.HR5-114 Long CryoTong 18 mm, 180° features the head in alignment with the handle of the CryoTong.

图片

图片

图片

图片

图片

图片
Vial Clamp™ – Straight
ApplicationsVial support and manipulation
FeaturesStraight end tipHemostat style closureDescription
The Vial Clamp™ – Straight is a chrome plated, hemostat style tool. It has a tip shaped to hold the storage vial of all the CrystalCap Systems™ straight when the clamp is closed. The clamp can be locked using the hemostat style closure. This clamp makes it easy to dip the storage vial into liquid nitrogen for crystal storage. The complete length of the clamp is straight, with an overall length of 195 mm. When the vial is placed in the clamp, the length of it is positioned perpendicular, 90° to the length of the clamp.
图片
CrystalWand™ Magnetic
ApplicationsCrystalCap Magnetic & CrystalCap Copper Magnetic handling toolDescription
The CrystalWand Magnetic is designed to be used exclusively with the CrystalCap Magnetic, CrystalCap Copper Magnetic, and CrystalCap HT systems during transfer of the caps from the vial to the goniometer head and from the goniometer to the vial. The 6 1/2” (165 mm) long chrome plated steel wand features a plastic housing enclosing a spring tensioned plunger that when depressed, moves a non-magnetic steel platform away from the magnet housed in the end of the wand. This causes the steel CrystalCap to detach from the wand and be placed readily into the vial or the CryoTong™. When the platform is retracted, the wand securely holds the steel CrystalCap Magnetic. The CrystalWand Magnetic 45° (McMiken Tool) offers the same functionality but is bent at a 45° angle at approximately 2.5 cm from the magnet end.HR4-729 CrystalWand Magnetic, StraightHR4-315 CrystalWand Magnetic, 45° (McMiken Tool)
图片

图片

图片
Vial Clamp™ – Curved
ApplicationsVial support & manipulation
FeaturesCurved end tipHemostat style closureDescription
The Vial Clamp – Curved is a chrome plated, hemostat style tool. It has a tip shaped to hold the storage vial of all the CrystalCap Systems at an angle when the clamp is closed. The clamp can be locked using the hemostat style closure. The end of the clamp, where the vial is held, is curved at either a 45°/135° or 110°/ 70° angle. When the vial is placed in the clamp, the length of it is positioned to the clamp at either of those same angles. The overall length of each clamp is the same, 195 mm.HR4-671 Vial Clamp – Curved 45°/135°HR4-672 Vial Clamp – Curved 110°/70°
图片

CrystalCap™ Holder
pplicationsCrystalCap support inside stainless steel dewars
FeaturesAdjustable heightSupports up to 8 CrystalCaps15 ml vial position for liquid propane500 and 1,000 ml versionsDescription
CrystalCap Holders are convenient stands for holding all CrystalCap™ systems in liquid nitrogen dewars during crystal cryogenic procedures. Available in two sizes. Both holders feature spring-clips to secure the CrystalCap Vials in the holder. Both stands have 3 inches of adjustable Z (height) which allows one to raise or lower the CrystalCaps to the appropriate height, depending upon the liquid nitrogen level in the dewar. Each holder is supplied with a socket driver for height adjustment.500 ml version holds five CrystalCaps, two 15 ml vials (for liquid propane procedures) and fits into the 500 ml dewar. 1,000 ml version holds eight CrystalCaps, two 15 ml vials (for liquid propane procedures) and fits into the 1,000 ml dewar.HR4-707 CrystalCap Holder – 500 ml
HR4-706  Replacement Height Adjustment Tool
图片

图片