上海金畔生物科技有限公司代理New England Biolabs(NEB)酶试剂全线产品,欢迎访问官网了解更多产品信息和订购。
产品信息
The NEBNext Poly(A) mRNA Magnetic Isolation Module is designed to isolate intact poly(A)+ RNA from 1-5µg of previously isolated total RNA. The technology is based on the coupling of Oligo d(T)25 to 1 μm paramagnetic beads which is then used as the solid support for the direct binding of poly(A)+ RNA. Thus, the procedure permits the manual processing of multiple samples and can be adapted for automated high-throughput applications. Additionally, magnetic separation technology permits elution of intact mRNA in small volumes eliminating the need for precipitating the poly(A)+ transcripts in the eluent. Intact poly(A)+ RNA which is fully representative of the mRNA population of the original sample can be obtained in less than one hour.
Note that for input amounts >5µg we recommend the NEBNext High Input Poly(A) mRNA Isolation Module (NEB #E3370).
- 产品类别:
- RNA Depletion & mRNA Enrichment Products,
- RNA Library Prep for Illumina,
- Next Generation Sequencing Library Preparation Products
-
产品组分信息
本产品提供以下试剂或组分:
NEB # 名称 组分货号 储存温度 数量 浓度 -
E7490S 4 NEBNext RNA Binding Buffer (2X) E7492AVIAL 4 1 x 7.2 ml Not Applicable NEBNext Wash Buffer E7493AVIAL 4 1 x 28.8 ml Not Applicable Nuclease-free Water E7495AVIAL 4 1 x 1.2 ml Not Applicable NEBNext Tris Buffer E7496AVIAL 4 1 x 6 ml Not Applicable NEBNext Oligo d(T)25 Beads E7499AVIAL 4 1 x 0.48 ml Not Applicable
-
E7490L 4 NEBNext RNA Binding Buffer (2X) E7492AAVIAL 4 1 x 28.8 ml Not Applicable NEBNext Wash Buffer E7493AAVIAL 4 2 x 57.6 ml Not Applicable Nuclease-free Water E7495AAVIAL 4 1 x 4.8 ml Not Applicable NEBNext Tris Buffer E7496AAVIAL 4 1 x 24 ml Not Applicable NEBNext Oligo d(T)25 Beads E7499AAVIAL 4 1 x 1.92 ml Not Applicable
-
-
特性和用法
需要但不提供的材料
- 96-well 0.2 ml PCR Plates and Microseal® 'B' Adhesive Sealer (BioRad MSB-1001) or 0.2 ml RNase-free tube.
- Magnetic rack or plate (e.g., NEBNext® Magnetic Separation Rack (NEB #S1515S), Alpaqua ® 96S Super Magnet Plate (#A001322), or equivalent)
- Thermal cycler or heat block
- Bioanalyzer® (Agilent Technologies, Inc.) or similar instrument and consumables.
-
优势和特性
应用特性
Isolation of poly(A)+ RNA transcript from Total RNA for RNA library preparation and sequencing.
操作说明、说明书 & 用法
-
操作说明
- Where can I find protocols for using NEBNext® RNA Library Prep reagents?
-
说明书
产品说明书包含产品使用的详细信息、产品配方和质控分析。- manualE7490
-
使用指南
- Getting Started with RNA-Sequencing (RNA-Seq)
FAQs & 问题解决指南
-
FAQs
- Can I isolate poly(A)+ mRNA directly from tissue lysis using the NEBNext® Poly(A) mRNA Magnetic Isolation Module (E7490)?
- Do I need two rounds of binding?
- Can I use the Oligo (dT)25 Magnetic Beads (NEB# S1419S) to isolate poly(A)+ mRNA for Next Generation Sequence applications?